EasyManua.ls Logo

Mitsubishi Electric FX3U SERIES - Drive to Increment - DRVI Instruction; Instruction Format

Mitsubishi Electric FX3U SERIES
282 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FX
3S
/FX
3G
/FX
3GC
/FX
3U
/FX
3UC
PLC User's Manual - Positioning Control Edition
Built-in Positioning Functions
8 1-Speed Positioning - DRVI/DRVA Instruction
8.2 Drive to Increment - DRVI Instruction
B - 122
8.2 Drive to Increment - DRVI Instruction
8.2.1 Instruction Format
1. Instruction Format
2. Data setting
*1. Setting range : -32,768 to +32,767 (excluding 0) for 16-bit operation
: -999,999 to +999,999 (excluding 0) for 32-bit operation
*2. Setting range : 10 to 32,767 Hz for 16-bit operation
For 32-bit operation, however, the setting range is as shown in the following table.
3. Devices
1 : Specify Y000, Y001, or Y002
*3
transistor output from the main unit, or specify Y000, Y001, Y002
*5
, or
Y003
*5
from a high-speed output special adapter
*4
.
*3. Y002 is not available in FX
3G PLC (14-point and 24-point type) and FX3S/FX3GC PLC.
*4. High-speed output special adapters can be connected only to the FX
3U PLC.
*5. To use Y002 and Y003 with a high-speed output special adapter, connect a second high-speed output
special adapter.
Note:
To use an FX
3U PLC of relay output type or triac output type, be sure to connect a high-speed output
special adapter.
Differential line drive type outputs will be used for the outputs of the high-speed output special adapter.
Operand type Description Data type
Specifies the number of output pulses (relative address).
*1
BIN16/32-bit
Specifies the output pulse frequency.
*2
Specifies the pulse output number.
Bit
Specifies the rotation direction signal output destination device number.
Pulse output destination Setting range
FX
3U PLC High-speed output special adapter 10 to 200,000(Hz)
FX
3S/FX3G/FX3GC/FX3U/FX3UC PLC Main unit (transistor output) 10 to 100,000(Hz)
Operand
type
Bit device Word device Others
System user Digit designation System user
Spe-
cial
unit
Index
Con-
stant
Real
num-
ber
Char-
acter
string
Pointer
XYMTCSD.b KnX KnY KnM KnS T C D R
U
\G
V Z Modify K H E ""P

4 5


4 5

1
2 3
FNC 158
DRVI
DRIVE TO
INCREMENT
D
16-bit
instruction
9 steps
DRVI
-
Continuous
execution
type
Instruction
symbol
Execution condition
32-bit
instruction
Instruction
symbol
Execution condition
DDRVI
-
Continuous
execution
type
17 steps
Command
input
FNC158
DRVI
S
1
S2
D
1
D
2
S
1
S
2
D
1
D
2
S
1
S
2
D
1
D
2
Downloaded from ManualsNet.com search engine

Table of Contents

Other manuals for Mitsubishi Electric FX3U SERIES

Related product manuals