PLC User's Manual - Positioning Control Edition
Example Connection
Appendix 2. MELSERVO-J3 Series
Appendix 2-3 Absolute Position Detection (Transistor Output)
Apx. - 22
3. FX
3GC/FX3UC PLC
*1. Be sure to use the class-D grounding method (grounding resistance: 100
or less).
*2. Extension blocks are used in the connection example.
Inputs and outputs built into the main unit are available in place of extension blocks.
FX3UC-32MT/D
DOCOM
46
22
DICOM
20
ABST 25
23
SD
Plate
CN1
24 V DC
COM1
FX2NC-16EYT
Y020
Y027
COM1
Y021
Y022
Y023
COM
X000
COM
X020
FX2NC-16EX
X031
X032
X033
X037
SON 15
ABSR 18
ABSM 17
ABSB0 22
ABST 25
ABSB1 23
Photo-
coupler
Photo-
coupler
Class-D
grounding
*1
*2
*2
ABS (bit0)
ABS (bit1)
Servo-ON
ABS transfer mode
ABS request
Send data ready
MR-J3A
Series servo
amplifier