FX
3S
/FX
3G
/FX
3GC
/FX
3U
/FX
3UC
PLC User's Manual - Positioning Control Edition
Example Connection
Appendix 4. MELSERVO-J2 (-Super) Series
Apx. - 40
Appendix 4-3 Absolute Position Detection (Transistor Output)
3. FX3GC/FX3UC PLC
*1. Be sure to use the class-D grounding method (grounding resistance: 100
or less).
*2. Extension blocks are used in the connection example.
Inputs and outputs built into the main unit are available in place of extension blocks.
SD
Plate
COM1
FX2NC-16EYT
Y020
Y027
COM1
Y021
Y022
Y023
COM
X000
COM
X020
FX2NC-16EX
X031
X032
X033
X037
SON
ABSR
ABSM
CN1B
SG
COM
10
13
5
9
8
DO1
TLC
ZSP
4
6
19
Photo-
coupler
Photo-
coupler
24 V DC
Class-D
grounding
*1
*2
*2
ABS (bit0)
ABS (bit1)
Servo-ON
ABS transfer mode
ABS request
Send data ready
MR-J2(S)A
Series servo
amplifier
FX3GC-32MT/D
FX
3UC-32MT/D
Downloaded from ManualsNet.com search engine