5. Hardware Settings
5.1. Settings of the CC-Link Master Station
5.1.1. CR75n-D/CRnD-700 series
The details of the setting of the master station are shown in the following. For details, please refer to "the
cc-Link system master local unit user's manual (volume on details)."
Figure 5.1-1 The outline of the CC-Link master-station unit (Q series)
As shown in Table 5-1, set up the rotary switch of the CC-Link master-station unit.
For details, please refer to "the cc-Link system master local unit user's manual (volume on details)."
Table 5.1-1 The setup of the CC-Link master-station unit (Q series)
Item Details of setting At shipping
Rotary
switch
②
number
X10:Set the ten digit of a station number
:
Set the ten digit of a station number
③Mode
0:Transmission speed 156kbps
1:Transmission speed 625kbps
2:Transmission speed 2.5Mbps
3:Transmission speed 5Mbps
:
Transmission speed 10Mbps
0 4
Notice) When the mode of the master station is changed, change the parameter "CCSPD" of
the robot controller.
Rotary switch (station number)