15
5.1.2. CR800-D series
The details of the setting of the master station are shown in the following. For details, please refer to
"MELSEC iQ-R CC-Link System Master/Local Module User's Manual (Startup)".
Figure 5.1-2 The outline of the CC-Link master-station unit (iQ-R series)
As shown in Table 5-1, set up the rotary switch of the CC-Link master-station unit.
For details, please refer to "MELSEC iQ-R CC-Link System Master/Local Module User's Manual
(Startup)".
Table 5.1-2 The setup of the CC-Link master-station unit (iQ-R series)
Item Details of setting At shipping
Example
of setting
Rotary
switch
Station
number
X10
Set the ten digit of a station number
0
0
X1
Set the ten digit of a station number
0
0
Mode
Set the mode
0Transmission speed 156kbps
1Transmission speed 625kbps
2Transmission speed 2.5Mbps
3Transmission speed 5Mbps
4Transmission speed 10Mbps
0 4
Notice) When the mode of the master station is changed, change the parameter "CCSPD" of
the robot controller.