3.2. Specification of the CC-Link Interface Card
Table 3.2-1 General Specification (Specification of HR575 Card)
Both bit data and word data can be
transmitted.
registers.
Type name of CC-Link interface card
Mountable option slot 1, 2, or 3
Number of mountable cards
It is not allowed to insert
multiple cards.
Version corresponding to CC-Link
The extended cyclic setup
is possible
Intelligent device station
Transient transmission is
not supported.
Supported station functionality
functionality is not
Can be set between station numbers
1 and 64
Set using the dip switches
on the card.
If two or more station
occupancy, it becomes
the continuation station
number.
10 M, 5 M, 2.5 M, 625 k, 156 kbps
Number of occupied stations
Can be set to occupy 1, 2, 3, or 4
stations.
Can be set to 1, 2, 4, or 8 multiple.
Number of I/O
points
Remote input (RX) 896 max. The last two points cannot
be used.
16 bits.
I/O
STOP2
-1 , -1
List of Robot
Parameters Used in
CC-Link" for details.
DIODATA
-1 , -1
CCERR 0
E7730 0
CCINFO 1 , 1 , 1
CCSPD
4
CCCLR
0
CCFIX
1
CCFIL
1000, 200
CCREFCYC
1
M_In/ M_Inb/ M_In8 / M_Inw/ M_In16
M_Out/ M_Outb/ M_Out8/ M_Outw/ M_Out16
M_DIn, M_DOut