7.1. Setting the parameter of CC-Link master station
Set it as the CC-Link master station that the robot's CC-Link interface card exists on the CC-Link
network. In case of Q series of the MELSEC sequencer, explain to the example the case that the
utility for setting the parameter for CC-Link communication is used.
In addition, please refer to "the cc-Link system master local unit user's manual (volume on
details)" for the details of the parameter setup which uses GX Developer.
(1) Connect the MELSEC sequencer with the personal computer by the USB cable, the RS-232C
cable, etc.
(2) Start GX Developer
(3) Select [on-line]-[PC read-out] from the menu, select the kind of connected cable, and read the
parameter and the program on GX Developer.
(4) Select the [parameter] icon in the left frame of GX Developer, and double-click the [network
parameter].
(5) Click the [CC-Link] button on the displayed "network parameter selection" screen.
(6) Set up the following on the displayed "network parameter setting" screen.
No. Item Details
1
The CC-Link master station specifies the head I/O
number of the unit which shows the mounting
position on the base board of the MELSEC
Blank 0060
2
connection
Set up all the number of connection of the slave
station connected on the CC-Link network.
64 1
3
Set up the device for refreshment of data
communications with slave station.
Blank
X1000
Y1000
4
Blank
5
information
Set up the type of remote station and local station
which connected.
Button
the
following