31
(7) Click the "Station information" button and set up the slave station.
No. Item Details Initial value
Setting
example
1
Station classification
Ver.1 remote I/O station
Ver.1 remote device
station
Ver.1 intelligent device
station
Ver.2 remote device
station
Ver.2 intelligent device
station
The robot's CC-Link interface card
specifies the "Ver.2 intelligent device
station."
In case of the 2nd switch (cc-Link
version) of DIP switch SW1 on the
CC-Link interface card is turned
"OFF", specify the "Ver.1 intelligent
device station."
Ver.1 remote
I/O station
Ver.2 intelligent
device station
2
Extended cyclic setup
1 fold setup
2 fold setup
4 fold setup
8 fold setup
Since the CC-Link version is "Ver.2"
in initial setting, the multiple setup is
possible.
By changing the multiple setup, it is
possible to increase the point of
remote I/O which can communicate,
and the register.
1 fold setup
1 fold setup
3
Number of occupancy
stations
One-station occupancy
To w -station occupancy
Three-station occupancy
Four-station occupancy
Specify the number of the stations
which the slave station occupies.
The a maximum of four stations can
be occupied.
One-station
occupancy
One-station
occupancy
4
Reservation / invalid
station specification
With no setup
Reservation station
Invalid station
In case of the slave station has
connected on the CC-Link network,
select the "No setup."
In the future, the "reservation station"
will be specified about the slave
station which is due to be connected
(extension).
And, the slave station which the error
does not detect at the time of error
occurrence specifies the "invalid
station."
With no
setup
With no setup
(8) If all are set up, confirm that no error by click [error-checking] button.
(9) Click the [finishing of the setting] button, and click the [finishing of setting] button on the "network
parameter setting screen."
(10) Click [on-line]-[PC write-in] from the menu of GX Developer, and write the parameter in the
MELSEC sequencer.
In addition, please refer to "the parameter setup by GX Developer" of "the cc-Link system master local
unit user's manual (volume on details)" for the details about the setup.