200
(2) Control data
*1 The range of 1
H
to 400
H
is available only in the E71 with the serial number (first five digits) of "15042" or later.
Device Item Setting data Setting range Set by
(S2)+0
Execution
type/completion
type
To open a connection, specify whether to use the
parameter settings of a programming tool or to use
the settings stored in the following control data
starting from (S2)+2.
• 0000
H
: Use the parameter settings of the
programming tool.
• 8000
H
: Use the settings of control data starting
from (S2)+2 to (S2)+9.
0000
H
,
8000
H
User
(S2)+1
Completion
status
Stores the status at completion.
• 0000
H
: Normal completion
• Values other than 0000
H
: Abnormal end (error
code)
System
(S2)+2
Usage setting
area
Specify the application of a connection.
• Usage of fixed buffer (b0)
0: For sending or fixed buffer communications are
not performed
1: For receiving
• Destination existence confirmation (b1)
0: No confirm
1: Confirm
• Pairing open (b7)
0: Disable
1: Enable
• Communication method (protocol) (b8)
0: TCP/IP
1: UDP/IP
• Fixed buffer communication procedure (b10, b9)
00: Procedure exists
01: No procedure
10: Predefined protocol
• Open system (b15, b14)
00: Active open or UDP/IP
10: Unpassive open
11: Fullpassive open
As described in the left User
(S2)+3
Own station port
No.
Specify the port number of the own station.
401
H
to 1387
H
, 138B
H
to FFFE
H
User
(S2)+4
(S2)+5
Destination IP
address
Specify the IP address of the connected device.
1
H
to FFFFFFFF
H
(FFFFFFFF
H
:
broadcast)
User
(S2)+6
Destination port
No.
Specify the port number of the connected device.
1
H
to FFFF
H
*1
(FFFF
H
:
broadcast)
User
(S2)+7
(S2)+8
(S2)+9
Destination MAC
address
Specify the MAC address of the connected device.
000000000000
H
to
FFFFFFFFFFFF
H
User