Loading...
APP - 17
APPENDICES
(7) Description of sample data
(a) Motion CPU area
1) SV13 (Q170MS_SV13_MT2)
a) Base setting
Setting items Description
Extension base
Stage 1 Nothing
Stage 2 Nothing
Stage 3 Nothing
Stage 4 Nothing
Stage 5 Nothing
Stage 6 Nothing
Stage 7 Nothing
b) Multiple CPU setting
Setting items Description
Operating mode All station stop by stop error of CPU 1/2
Multiple CPU synchronous startup setting Set CPU No. 1/2 to synchronous startup
c) Multiple CPU high speed transmission area setting
CPU
CPU specific send range
Points (k)
User setting area Automatic refresh
Points Start End Points
No.1 7 7022 G10000 G17021 146
No.2 7 6482 G10000 G16481 686
d) Automatic refresh setting
• CPU No.1 (Receive)
Setting No.
Automatic refresh
CPU specific send range(U3E0\)
Points Start End Start End
1 28 M3072 M3519
G17022 G17049
2 118 D640 D757
G17050 G17167
• CPU No.2 (Send)
Setting No.
Automatic refresh
CPU specific send range(U3E1\)
Points Start End Start End
1 46 M2000 M2735
G16482 G16527
2 320 D0 D319
G16528 G16847
3 320 #8000 #8319
G16848 G17167