EasyManua.ls Logo

Mitsubishi QD70P4 - Page 179

Mitsubishi QD70P4
224 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11 - 11 11 - 11
MELSEC-Q
11 SUB FUNCTIONS
[2] Precautions for control
(1) At the set speed of 1 (pulse/s), the set acceleration/deceleration time is
ignored.
(2) In the acceleration/deceleration pattern where the movement amount is
small relative to the acceleration/deceleration time and a constant-speed
part does not exist, operation is not performed at the set
acceleration/deceleration time. In such a case, review the setting details.
(3) If operation is performed with 0 set as the bias speed at start in the control
method of "1-axis linear control (ABS)" or "1-axis linear control (INC)"
positioning control, an error "Movement amount shortage at 0 bias speed"
(error code: 514) may occur due to shortage of the movement amount.
Perform either of the following operations (a), (b) as the corrective action at
error occurrence.
(a) Set 1 (pulse/s) or more to "
Pr. 6
bias speed at start".
(b) If the movement amount is 32 (pulse) or less, set the value equal to or
less than the initial value (1000ms) to "
Da. 3
ACC/DEC time" and
"
Da. 4
DEC/STOP time".

Table of Contents