IPB-5000A
10. External Communication Function
10-14
10) Control (Q)
S
pecified
Code
Item Contents
Q00
W1 Control Mode
Q01
W2 Control Mode
00: Constant Current
01: Constant Voltage
02: COMBI
03: Constant Power
Q02
Selection of W1 Weld
Stop Input
Q03
Selection of W2 Weld
Stop Input
00: OFF
01: Displacement
02: Current
03: Voltage
Q04
W1 Weld Stop
Condition
Q05
W2 Weld Stop
Condition
n.nnkA
n.nnV
+/-nn.nnnmm

Table of Contents