IPB-5000A
11. Specifications
11-3
Items
Common Specification in IPB-5000A
Monitor Computing
Range
Set at MONITOR MODE.
EXCLUDE SLOPE: Computing a monitored value excluding
Slope Period
INCLUDE SLOPE : Computing a monitored value including
Slope Period
PARITY/WE1STOP
Input Selection
Set at SCHEDULE#.
EXT.(P) : Parity Input at External Input Terminal Pin 14
EXT. (NP) or PANEL: WELD1 Stop Input at External Input
Terminal Pin 14
Starting Time of
detecting No Current
or No Voltage
Set at NO CURR MONITOR START.
00 to 10ms (Starts to detect No Current or Voltage after the
set period)
Pulse Monitoring
Start Time
Set at PW MONITOR START.
00 to 10ms (Starts the pulse monitoring after the set period)
NG Output Setting
Set at NG OUTPUT.
NORMALLY CLOSE : Closed with Power Supply turned on
and open with NG generated
NORMALLY OPEN : Closed with NG generated
READY Output
Setting
Set at READY OUTPUT.
WELD ON : Closed with Weld Current Supply ready
POWER ON : Closed with IPB-5000A turned on
Operation
Environment
Temperature 5 to 40,
Humidity 90% or less (No condensation)