Equipment --- Section 5
Cayman 2005
175
If the Slide Room Fails to Operate:
Check the fuse and auto-reset circuit
breaker on the slide-out relay module locat-
ed adjacent to the inverter. If the fuses and
circuit breakers test okay, it will be neces-
sary to call and obtain mechanical assistance
to correct the problem.
To Extend the Bedroom Slide-out:
• Confirm that there is at least five feet
of clearance outside the motorhome for
the slide-out room to extend.
• Ensure the ignition key is in the OFF
position.
• The house batteries are fully charged.
• The battery cut-off switch must be in
the ON position. The switch is on the
monitor panel.
• Ensure all people, pets and objects are
clear of the slide-out room path.
• Press and hold the rear slide-out room switch in the OUT position. The slide-out room will
slowly move to the OUT position. Release the switch to stop room movement. To continue the
room movement, push and hold the switch in.
• Release the slide-out switch when the room is fully extended (a change in motor sound indi-
cates extension). The slide-out drive motor will stop automatically.
• Level the motorhome with the leveling system.
WARNING:
Firmly latch all cabinet doors adjacent to the bedroom slide-out before extending or
retracting the room. Damage to doors or fascia can occur.
CAUTION:
Dirt and grit trapped under the slide could result in damage to the floor. Continuous
operation of the slide-out could cause a drain on the house batteries and damage to
the motor from overheating.
NOTE:
Do not leave the slide-out extended during severe weather. Conditions such as high
winds or heavy rain may cause damage.
NOTE:
Perform the slide-out room operation with the air suspension system full. Extensive
damage could occur to the slide-out room and awning when extending the slide-out
room in snow, sleet, ice or freezing rain conditions. In such conditions, if the slide-
out room is extended, clear the awning and ensure free movement prior to operating
the slide-out room.
080473
Double Slide Relay Module
080429
Triple Slide Relay Module
Synchronizer for dual motor slide-outs.
080429