LP-Gas Systems --- Section 7
Cayman 2005
241
Tank Operation
• Manually open the primary shut-off valve located on the LP-Gas tank.
• Turn on the electric LP-Gas valve to allow gas to flow to the appli-
ances.
• Turn off the electric valve and primary valve on the LP-Gas tank when
the tank is being filled, when driving, in between trips and when in
storage.
• Hand-tighten the primary valve only. Do not use a wrench or pliers, as
this will over-tighten the valve.
• The primary valve is designed to be closed by hand, over-tightening
may permanently damage the valve seat.
NOTE:
In some states and Canadian provinces, it may be illegal to
drive the motorhome while primary valve on the LP tank is
open.
Exterior Gas Line Hook-Up Prep:
An auxiliary remote LP-Gas hook-up is for external LP-Gas accessories and is to be used for exter-
nal components only. For safety, only approved LP-Gas quick disconnect fittings and flexible hose
should be used to connect external accessories to the rome hook-up. A LP-Gas Quick Disconnect fitting
should be installed by a qualified agency as defined in the Nation Fire Protection Associates NFPA
(Fire) 54-02 code.
NOTE:
Every time the remote hook-up is
used, check for gas leaks on all
connections. If a leak is detected,
turn off the primary valve at the
main LP-Gas tank. Contact a
qualified service center for the
necessary repairs.