Section 7 --- LP-Gas Systems
Cayman 2005
240
1. Turn off pilot lights, all appliances and the engine. Close all
vents, doors and windows to prevent vapors from entering
the motorhome. Turn off Electric Valve.
2. Remove dust cover. Screw LP nozzle to fill valve.
3. Turn on dispensing pump, then open 80% bleed valve.
4. Open valve on fill nozzle and dispense liquid into the tank.
5. Close valve on fill nozzle as liquid just begins to expel from
80% bleed valve. The overfill protection valve prevents
filling the tank to more than 80% of the rated capacity.
6. Close 80% valve and shut off dispensing pump.
7. Open high-pressure bleed valve on fill nozzle to remove pres-
sure between dispensing pump and fill nozzle. Remove noz-
zle from the fill valve.
8. Install the dust cover.
9. LP-Gas appliances (especially the refrigerator) may have diffi-
culty starting after a period of non-use. To speed the process
of supplying fresh fuel to the appliances, light the stove
first.
WARNING:
It is common for small amounts
of liquid propane to escape and
evaporate during the refueling
process. Protect bare skin.
Instant freezing will occur if
exposed to LP-Gas.
CAUTION:
Pressure inside LP-Gas tanks
can reach over 200 psi when
exposed to direct sunlight. A
high-pressure safety relief valve
will purge excess high pres-
sure, if necessary. LP-Gas will
stop vaporizing as the LP-Gas
tank temperature approaches -
44º F.
050269
Electric LP-Gas
Valve Switch
Exterior Gas
Line Hook-up
Electric
LP-Gas
Switch
Indicator
80%
Valve
Fill
Valve
Typical Fill Nozzle at Fill Stations
050271