EasyManuals Logo

Monarch NICE 5000 User Manual

Monarch NICE 5000
233 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #109 background imageLoading...
Page #109 background image
NICE5000 User Manual 6 Function Code Table
- 107 -
Function
Code
Parameter Name Setting Range Default
Unit
Property
F6-01
Bottom oor of the
elevator
1 to F6-00
1
-
F6-02
Parking oor F6-01 to F6-00
1
-
F6-03
Fire emergency
oor
F6-01 to F6-00
1
-
F6-04
Elevator lock oor F6-01 to F6-00
1
-
F6-05
Service oors 1 0–65535
65535
-
F6-06
Service oors 2 0–65535
65535
-
F6-07
Service oors 3 0–65535
65535
-
F6-08
Service oors 4 0–65535
65535
-
F6-09
Elevator function
selection 1
Bit0: Disability function
Bit1: Disabling returning to base
oor for verication
Bit2: Re-leveling function
Bit3: Door pre-open function
Bit4: Stuck hall call cancellation
Bit5: Peak service
Bit6: Down collective selective
peak service
Bit7: Fault auto reset
Bit8: Time-based service oor
function
Bit9: Disabling reverse oor
number clear
Bit10: Buzzer not tweet upon re-
leveling
Bit11: Car call deletion
Bit12: Hall call deletion
Bit13: Timed elevator lock
Bit14: Arrival gong disabled at
night
Bit15: Reserved
32768
-

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Monarch NICE 5000 and is the answer not in the manual?

Monarch NICE 5000 Specifications

General IconGeneral
BrandMonarch
ModelNICE 5000
CategoryController
LanguageEnglish

Related product manuals