EasyManuals Logo

Monarch NICE 5000 User Manual

Monarch NICE 5000
233 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #112 background imageLoading...
Page #112 background image
6 Function Code Table NICE5000 User Manual
- 110 -
Function
Code
Parameter Name Setting Range Default
Unit
Property
F6-17
Fire emergency
function selection 1
Bit0: Fire emergency 1 door 1
valid
Bit1: Fire emergency 1 door 2
valid
Bit2: Nearest oor for re
emergency
Bit3: Opposite door control
unchanged
Bit4: Reserved
Bit5: Retentive at power failure
Bit6 to Bit7: Reserved
Bit8: Fire emergency indicator
blinking at re emergency 1
Bit9: Fire emergency indicator
steady ON at re emergency 1
Bit10: Fire emergency tone
discontinuous prompt at re
emergency 1
1283
-
F6-18
Fire emergency
function selection 2
Bit0: Fire emergency 2 door 1
valid
Bit1: Fire emergency 2door 2 valid
Bit2: Entering reghter operation
state automatically
Bit3: Fireghter switch
Bit4: Fire emergency switch
switchover
Bit5 to Bit6: Reserved
Bit7: Low speed door close
Bit8: Fire emergency indicator
blinking at re emergency 2
Bit9: Fire emergency indicator
steady ON at re emergency 2
Bit10: Fire emergency tone
prompt at intervals at re
emergency 2
Bit11: Exiting re emergency at
any oor
1291
-