7 Description of Function Codes NICE5000 User Manual
- 154 -
Bit Function Description Default
Bit5 Forced door close
If the door still does not close within the time set in Fb-
11 in automatic state, the system outputs the forced
door close signal; at this moment, the light curtain
becomes invalid and the buzzer tweets.
When the door lock is disconnected, this function is
invalid.
0
Bit6 Manual door
This function is used in applications where door open
and close are carried out manually.
After this function is enabled, normal door open/close
detection is invalid, and the system re-denes the door
lock judgment method to control door open/close.
0
Bit7
Cancelling door lock
auto-reset
Generally, when Err53 is reported, if the conditions of
door open limit valid and door lock release are satised,
the controller resets Err53 automatically. A maximum of
three times of auto reset is allowed.
If this function is enabled, the controller does not reset
Err53 automatically.
0
Bit8
NO/NC output
selection of shorting
PMSM stator
contactor
Bit8 = 0: NC output contactor (recommended)
The shorting PMSM stator contactor closes during
running and opens at stop.
Bit8 = 1: NO output contactor
The shorting PMSM stator contactor opens during
running and closes at stop.
0
Bit9
Door lock circuit
contactor output
monitoring
This function is enabled when the door pre-open module
is used.
0
Bit10
Cancelling
overspeed
protection
If this function is enabled, the controller does not detect
the overspeed fault (Err56).
0
Bit11
Car call executed
rst
The system responds to hall calls only after executing
all car calls.
0
Bit12
Car call assisted
command in single
door used as
disability function
The auxiliary command terminal (CN8) on the CTB can
be set for input of the disability calls (folding command
not required).
0
Bit13
Folding command
used as disability
function and back
door function
It is valid only when the function of Bit14 is enabled.
Bit13 = 1: Disability
Bit13 = 0: Back door
0
Bit14
Car call command
folding
Function disabled: CN7 is used for front door calls or
ordinary calls, and CN8 is used for back door calls or
disability calls.
Function enabled: For CN7 and CN8, inputs 1 to 16 are
used for front door calls or ordinary calls, and inputs 17
to 32 are used for back door calls or disability calls.
0