Bit Function Description Default
Bit12 Reserved
- 0
Bit13 Reserved
- 0
Bit14
Opening door by
holding down the
door open button
In the re emergency state, the door open process can
be completed only by holding down the door open button
until the door open limit is reached. Otherwise, it will be
switched over to door close automatically.
1
Bit15
Automatic door
open after arrival
at re emergency
oor
The elevator automatically opens the door after arrival at
the re emergency oor.
0
Function Code Parameter Name Setting Range Default Unit Property
F6-22
Elevator lock start time 00.00–23.59
00.00 HH.MM
F6-23
Elevator lock end time 00.00–23.59
00.00 HH.MM
Within the time period set in these parameters, the elevator automatically runs to the
elevator lock oor and enters the elevator lock state.
Function Code Parameter Name Setting Range Default Unit Property
F6-24
Attendant function selection 0–65535
0 -
It is used to select the attendant-related elevator functions. Each bit of the function code
denes a function, as described in the following table.
If a bit is set to 1, the function indicated by this bit is enabled; if this bit is set to 0, the
function is disabled.
The functions dened by the binary bits are described in the following table.
Bit Function Description Default
Bit0
Calls cancelled after
entering attendant state
All car calls and hall calls are cancelled after the
system enters the attendant state for the rst
time.
0
Bit1
Not responding to hall
calls
The car blinks inside, prompting there is a hall
call, but the system does not respond.
0
Bit2
Attendant/Automatic state
switchover
If this function is enabled, the setting of F5-00 is
valid.
0
Bit3
Door close at jogging
The elevator door closes after the attendant
presses the door close button manually.
0
Bit4
Automatic door close
It is the same as the normal state. After the door
open holding time is reached, the door closes
automatically.
0
Bit5
Buzzer tweeting at
intervals in attendant
state
When the hall call oor and the car call oor are
different, the buzzer tweets 2.5s at intervals.
0