8 Troubleshooting NICE5000 User Manual
- 216 -
Fault
Code
Name Possible Causes Solution Level
Err57
Serial
peripheral
interface (SPI)
communication
abnormal
The SPI communication
is abnormal. No correct
data is received with 2s
of DSP communication.
101, 102: Check the wiring between
the control board and the drive
board.
103: Contact the agent or Monarch.
5A
Err58
Shaft position
switches
abnormal
1:
•
The up slow-down
and down slow-down
are disconnected
simultaneously.
•
The up limit
feedback and down
limit feedback
are disconnected
simultaneously.
1:
•
Check whether the states (NO,
NC) of the slow-down switches
and limit switches are consistent
with the parameter setting of the
MCB.
•
Check whether malfunction of
the slow-down switches and limit
switches exists.
4B
Err60
Leveling signal
abnormal
1: The up and down
leveling signals are lost.
2: The up leveling signal
and door zone signals
are lost.
3: The down leveling
signal and door zone
signals are lost.
4: All the up and down
leveling signals and door
zone signals are lost.
1 to 4:
Check whether the leveling signals
and related parameters are set
correctly.
3B
Err61
Leveling signal
abnormal
1: The door zone signal
is stuck.
2: The up and down
leveling signals are
stuck.
3: The up leveling signal
and door zone signals
are stuck.
4: The down leveling
signal and door zone
signals are stuck.
5: All the up and down
leveling signals and door
zone signals are stuck.
1 to 5:
Check whether the leveling signals
and related parameters are set
correctly.
3A