AWK Series User Manual
43
When prompted, select which active sessions you want to terminate.
Click TERMINATE to end the selected sessions. The user will be logged out of the corresponding interfaces
immediately.
Edit the Password Policy
To edit the password policy, click Password Policy under Account Management in the function menu
tree.
Minimum Length
Setting
Description
Factory Default
8 to 63
Specify the required user account password length based on
your organization’s password length policy. To comply with
IEC 62443 requirements, the minimum length starts at 8.
8
Password Validation Rules
Setting
Description
Factory Default
Selectable checkboxes
Select check box to enforce the required password
complexity:
At least one digit (0-9)
At least one upper case letter (A-Z)
At least one lower case letter (a-z)
At least one special character (~!@#$%^&*-_|:;,.<>{}[]())
Unchecked