MiiNePort E2/E3 Introduction to SCM (Serial Command Mode) Command Set
A-3
Command Code for Getting the Configuration
Device Name
Command code: BN
Command parameters: N/A
Reply parameters: MiiNePort’s name.
?GBN
System requests configured device name for this MiiNePort.
!GBN0MiiNePort_E2_9527
MiiNePort reports device name as ‘MiiNePort_E2_9527’
Console Password
Command code: BP
Command parameters: N/A
Reply parameters: MiiNePort’s console password.
?GBP
System requests console password for this MiiNePort.
!GBP01234
MiiNePort reports console password as 1234’.
Web console
Command code: BH
Command parameters: N/A
Reply parameters: 1 and web console TCP port separated by a semicolon (;) if web console is enabled, or a 0
if it is disabled.
?GBH
System requests http console setting for this MiiNePort.
!GBH01;80
MiiNePort reports http console as Enableand http port as 80’.
Telnet console
Command code: BT
Command parameters: N/A
Reply parameters: 1 and telnet console TCP port separated by a semicolon (;) if telnet console is enabled, or
a 0 if it is disabled.
?GBT
System requests telnet console setting for this MiiNePort.
!GBT01;23
MiiNePort reports telnet console as Enableand telnet port as 23’.
Auto configuration
Command code: BA
Command parameters: N/A
Reply parameters: 1 if Auto configuration is enabled, 0 otherwise.
?GBA
System requests Auto configuration setting for this MiiNePort.
!GBA01
MiiNePort reports Auto configuration as Enable’.

Table of Contents