Part Number STH034 3/12 37
13. Remove steel top panel. Check that the black
chute cover is sitting securely on the chute. The
ice Machine will not operate properly if it is out of
place.
14. The CO
2
and Water Regulator gauges can be
viewed through the panel windows, but the side
panel will require removal if the regulators need
adjustment.
15. Remove other side panel to access board
connections.
16. Install quick disconnect fittings from box of parts
supplied with BIC, on existing supply CO
2
and
water hose.
17. Confirm correct orientation of fittings.
18. Install drain hose on BIC and cut to proper length
(do not leave loops in drain).
19. Connect water and CO
2
hoses to BIC (quick
disconnect fittings).
20. Coil excess tubing and secure with tie straps.
21. Check water and CO
2
pressures (check while
using).
22. Check that board connections are secure, and did
not vibrate loose during shipment.
23. Check that both micro switches are in line with the
motor above the blenders.
24. Check the blender door sensor positions.
25. Reinstall side panels.
26. Push BIC into place.