Part Number STH034 3/12 69
13. Soak the following parts for 20 minutes in
cleaning solution. Rinse the parts thoroughly.
Soak the removed parts in sanitizing solution for
10 minutes and wipe them down.
If solution is left on these parts, they will rust.
2 chute parts
gasket
dispense wheel and housing
small washer
14. Wipe the inner ice bin wall with cleaning solution.
Rinse with a clean towel soaked in clean water
and wipe dry. Repeat with sanitizer solution.
Rinse with a clean towel soaked in clean water
and wipe dry.
15. With a bottle brush, brush the ice nozzle at bottom
of ice bin with cleaning solution. Rinse with a
clean towel soaked in clean water and wipe dry.
Repeat with sanitizer solution. Rinse with a clean
towel soaked in clean water and wipe dry.
16. Use an approved Ice Machine cleaning solution
as noted below.
NOTE: For safety and maximum effectiveness, use
the solution immediately after dilution.
Mix 5 fl. oz. (142 ml) “LIME-A-WAY” (Economics
Laboratory, Inc.) with 1 gallon (3 l) of warm water
or follow the dilution instructions and warnings on
an ice machine descaler bottle.