74 Part Number STH034 3/12
11. Verify the compressor rocker switch is in the OFF
position, then reconnect power and run the
gearmotor for 15 minutes. Perform the following
procedures during the 15 minute period:
• Remove ice compression nozzle from
evaporator and soak in cleaning solution.
• Descale drain pan by gently flexing, then
remove any scale residue.
• Inspect water feed and drain lines and clean
as needed.
• Connect ice transport tube direct to
evaporator and secure with hose clamp.
12. Disconnect power, then drain the water from the
evaporator and reservoir through the evaporator/
reservoir drain line - Using a pitcher, fill and drain
the evaporator/reservoir 4 times and reinsert the
hose into the hose clip.
13. Refer to chart and premix water and sanitizer.
14. Fill reservoir and evaporator with sanitizer/water
solution.
15. Verify the compressor rocker switch is in the OFF
position, then reconnect power and run the
gearmotor for 10 minutes.
Amount of
Luke Warm Water
Amount of Sanitizer
1 Gallon (4 L) Water 1/2 ounce (15 ml)