Part Number STH034 3/12 75
16. During the 10 minute period rinse cleaner from
compression nozzle with potable water and then
soak in sanitizer/water solution.
17. Move the compressor rocker switch to the ON
position. The ice machine will make ice with the
sanitizer/water solution and deposit the ice in the
bin/dispenser. Make ice for 5 minutes - add
sanitizer/water solution as the water level in the
reservoir drops.
NOTE: Do not allow the sanitizer/water level to drop
below the sensing probes. The ice machine will start a
20 minute delay period if the sensing probes lose
contact with the water for more than 10 seconds.
18. Move the compressor rocker switch to the OFF
position and disconnect power.
19. Drain the evaporator/reservoir and reinsert the
drain hose into the hose clip.
20. Reinstall the ice compression nozzle and
reservoir cover.
21. Remove blocking from under reservoir float and
reinstall reservoir cover.