Feeder overtime alarm: Feeders begin receiving feed when the last pan sends a
signal. Feed distribution continues until the pans are full. If the feed distribution is
longer than the user-defined time, the feeder active sensor should generate an
alarm.
Feeder under time: Feeder under time defines the time required to generate an
alarm when the feeder is not active.
o
Stop feeding System: If enabled, the controller stops the feeding cycle once a cross over
runtime is detected.
16.3 Configuring the Silo
Silo content is determined by weight using load cells attached to the silo legs.
Silo weight increases when feed is delivered
Silo weight decreases when feed is distributed to birds
1. Go to Flock > Silo Management.
The screen displays the amount of feed remaining in each silo, in quantity and percentage of the
total capacity.
2. Enter the amount of feed in each silo. Range: 0 50000 kgs.
3. To specify the feed type, click Feed Supply. Click Feed Type and select the type.

Table of Contents

Other manuals for Munters Trio Poultry Controller

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Munters Trio Poultry Controller and is the answer not in the manual?

Munters Trio Poultry Controller Specifications

General IconGeneral
BrandMunters
ModelTrio Poultry Controller
CategoryController
LanguageEnglish

Related product manuals