EasyManuals Logo

Munters Trio Poultry Controller User Manual

Munters Trio Poultry Controller
206 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #154 background imageLoading...
Page #154 background image
© Munters AB, 2020 154
18 Defining the Expected Bird Weight
TRIO collects bird weight data. Factors to set up when configuring how TRIO measures weight:
Reference Bird Curve: The reference weight is a value that reflects the birds’ expected target
weight.
o
Enabled: TRIO provides a weight curve (by growth day). The user can choose an industry
standard template or manually define a curve.
o
Disabled: TRIO provides a reference weight that can be edited.
Separate male/female weighing: When enabled:
o
Scales can be defined as male, female, or both.
o
Weight range can be specified for both genders.
o
If the bird curve is enabled, there are separate curves for each gender.
To enable editing the weight range and bird scale definition, define at least one scale in
Devices & Sensors. Two bird scales are required for weighing male and female bird
separately.
18.1 Reference Bird Curve
As an option, TRIO provides a default growth curve. If required, you can edit the growth days and bird
weights.
Curve Enabled
Curve Disabled
18.1.1 C
URVE
E
NABLED
1. To enable a bird curve, go to System > Control Strategy > Scales .

Table of Contents

Other manuals for Munters Trio Poultry Controller

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Munters Trio Poultry Controller and is the answer not in the manual?

Munters Trio Poultry Controller Specifications

General IconGeneral
BrandMunters
ModelTrio Poultry Controller
CategoryController
LanguageEnglish

Related product manuals