Opus Control Wiring and Programming
Installaon Manual
P/N C-00139 Rev 3-9-18
Nabco Entrances Inc. S82 W18717 Gemini Drive Muskego, Wisconsin 53150
Phone: (877) 622-2694 Fax: (888) 679-3319 www.nabcoentrances.com
NABCO hours of Operaon: Monday to Friday 8:00 a.m.- 4:30 p.m. (Central Time)
Turn OFF all power to the Automatic Door if a Safety System is not working.
Instruct the Owner to keep all power turned OFF until corrective action can be achieved
by a NABCO trained technician. Failure to follow these practices may result in serious
consequences.
NEVER leave a Door operating without all Safety detection systems operational.
WARNING
Table of Contents
CHAPTER1: SAFETY ............................................................. 3
CHAPTER2: SCOPE .............................................................. 4
SECTION 2.1: To the Installer ......................................................................4
SECTION 2.2: Objecve ...........................................................................4
CHAPTER3: FEATURES ........................................................... 4
CHAPTER4: SPECIFICATIONS ..................................................... 4
SECTION 4.1 General Specicaons .................................................................4
SECTION 4.2 Electrical Specicaons ................................................................5
SECTION 4.3 Output Power Guidelines ..............................................................5
CHAPTER5:120 VAC GENERAL WIRING ............................................ 6
CHAPTER6: THE OPUS CONTROL .................................................. 7
CHAPTER7: THE ROTARY DIAL .................................................... 7
CHAPTER8: LCD CATAGORY SCREENS .............................................. 8
SECTION 8.1: Level One: Specicaon Screens ........................................................8
SECTION 8.2: Level Two: Access Screen ..............................................................9
SECTION 8.3: Level Three and Four: Seng Category and Menu Items ...................................10
CHAPTER9: PROGRAMMING MENUS ............................................. 11
SECTION 9.1: Base Sengs .......................................................................11
SECTION 9.2: Movement Sengs ..................................................................11
SECTION 9.3: Oponal Sengs ....................................................................12
SECTION 9.4: Output Sengs .....................................................................14
SECTION 9.5: Input Sengs .......................................................................15
SECTION 9.6: History Seng ......................................................................16
SECTION 9.7: Test Open ..........................................................................16

Table of Contents

Other manuals for Nabco Opus Control

Questions and Answers

  • R
    Rebecca GarciaAug 21, 2025
    Why does my Nabco Opus Control Controller not react to the activation signal?
    • M
      marshjulieAug 21, 2025
      If your Nabco Controller isn't reacting to the activation signal, start by checking the main screen to see if 'IN' or 'EXT' highlights when the signal is applied. If not, inspect the wiring and the activation device. Also, check if 'BA' is highlighted. If a 4-wire switch is used, ensure 'Input BA Circuit' is set to 'Normally Closed'. If a 3-wire switch or no switch is used, it should be set to 'Normally Open'. If the status shows 'Stopped' with the door closed and 'BA' is not highlighted, power cycle the controller. Ensure you navigate back to the main screen for the activation signal to function.
  • G
    ghernandezSep 4, 2025
    What to do if my Nabco Opus Control Controller door stays open after manually opening it?
    • W
      William TurnerSep 4, 2025
      If the door stays open after manually opening it, the 'Manual Open Function' might be set to 'No Action' and the 'Manual Open Sensitivity' to '0'. If you want 'No Action', change 'Manual Open Sensitivity' to any value other than '0'.
  • C
    collinscarolSep 2, 2025
    Why does my Nabco Opus Control Sim Pair behave oddly?
    • K
      Kelly MooreSep 3, 2025
      If your Nabco Controller Sim Pair is behaving oddly, it might be due to incorrect communication between the controls. Perform a 'copy data' from one control to the other. After doing this, one control should display 'Type 1' on the main screen, and the other should display 'Type 2'. The specific type assigned to each doesn't matter, but they must be different.
  • J
    janetclarkSep 1, 2025
    What causes a Nabco Opus Control Controller 'Drive Circuit' error?
    • J
      John MacdonaldSep 1, 2025
      A 'Drive Circuit' error on your Nabco Controller can stem from a few causes. It could be due to abnormal voltage at the Motor Circuit, in which case you should check all connections between the Control and Motor. Another cause might be abnormal current draw from the motor, so inspect the Motor Fuse. Electrical noise may also trigger a false error; if the error doesn't happen repeatedly, it's likely not a significant issue.
  • J
    josetaylorAug 31, 2025
    What to do if the Nabco Opus Control Controller closing functions do not work when opened manually?
    • R
      Rodney HansonAug 31, 2025
      If the closing functions aren't working after manually opening the door, change the 'manual open function' setting to something other than 'no action'. 'Stop and close' is often the best option.
  • K
    Kim LarsonAug 29, 2025
    Why are my Nabco Controller Double Egress pairs not Synchronizing?
    • D
      Deborah Yates DVMAug 29, 2025
      If your Double Egress pairs aren't synchronizing, try these steps: * Remove the CANbus cable. * Set both Controls as single doors. * Parallel the activation signal between both Controls. * Ensure safety signals are connected only to their respective door's Control. Also, make sure both controls are set to 'Double Egress'. Consider reviewing the 'Sim Pair behaves oddly' section for additional guidance.
  • M
    Melissa FletcherAug 28, 2025
    How to fix Nabco Controller communication issues?
    • K
      Kendra JohnsonAug 28, 2025
      To address communication issues with your Nabco Controller, check the CAN-bus cable connecting the two Opus Controls.
  • M
    Marie DavilaAug 27, 2025
    What to do if my Nabco Opus Control door does not always close during Latch Check?
    • Q
      qwoodsAug 27, 2025
      If the door doesn't always close during the Latch Check, try increasing the latch check speed. Alternatively, increase the operator arm preload, or, if you have a GT710, increase the spring tension on the hydraulic closer.
  • B
    Brian SmithAug 25, 2025
    Why is it hard to manually open my Nabco Opus Control door?
    • J
      Jake CombsAug 26, 2025
      If you're finding it hard to manually open your Nabco Controller door, consider the following: * Check that the shoe position and rod length match the dimensions specified in the manual. * Reduce the preload on the operator. For GT8500 models, ensure the preload is at most one notch on the operator spline to comply with ANSI 156.19. * Re-enter '0' for 'hold closed force' under 'optional settings'. Even if the software indicates it's already set to '0', re-entering it can resolve the issue, especially on early Opus controls.
  • J
    Jason MitchellAug 23, 2025
    What to do if I get a Recycle Warning on my Nabco Controller?
    • D
      Daniel MorrowAug 23, 2025
      If you're getting a Recycle Warning on your Nabco Controller, inspect the door and door path for any resistance to movement. Adjusting the Recycle Sensitivity may also be necessary.

Summary

CHAPTER 1: SAFETY

General Safety Recommendations

Essential safety practices for installation and operation of automatic doors.

CHAPTER 4: SPECIFICATIONS

CHAPTER 5: 120 VAC GENERAL WIRING

CHAPTER 8: LCD CATAGORY SCREENS

CHAPTER 9: PROGRAMMING MENUS

Base Settings

Configures fundamental parameters like operator type and door handing.

CHAPTER 10: COMMON PROGRAM ADJUSTMENTS

CHAPTER 11: FOLD DOOR WIRING DIAGRAMS

Switches and Sensors

Illustrates wiring for fold door activation and safety sensors.

CHAPTER 12: SWING DOOR WIRING DIAGRAMS

Safety

Illustrates wiring for safety sensors and their connections.

CHAPTER 12: SWING DOOR WIRING DIAGRAMS

CHAPTER 13: TROUBLESHOOTING

Programming Issues

Lists common programming problems and their solutions.

Error Messages

Explains error codes and their resolutions.

Nabco Opus Control Specifications

General IconGeneral
BrandNabco
ModelOpus Control
CategoryController
LanguageEnglish

Related product manuals