6-11
Key Point:
• Do not include the terminator in the transmission data. The terminator is added automatically.
• When “STX exist” is specified for the header, do not add the header to the transmission data. The
header is added automatically.
• When using the communication block (AFP2803 RS232C type) and setting the RS/CS to be valide,
transmission does not take place until CS (Clear to Send) turns on. If you are not going to connect to
the other device, set the RS/CS to be invalid.
• The maximum number of transmission bytes “n” is 2048. (However, the header and terminator are
included.) When using the header and terminator subtract the byte numbers for them.
• The contact numbers in parentheses refer to COM port 2.
Reference: <9.2 Appendix (Time Chart)>
Note: Followings can be set using F159 (MTRN) as well as the data transmission.
1. Switching the applications of COM port.
2. Communication conditions.
Reference: <Capter 8 Applications) > <9.6 F159 (MTRN)/F161 (MRCV) instructions>