User Guide
245
www.nec-computers.com
0B80 BMC Memory Test Failed. Turn off the power once and then on again to start the
server. If the error cannot be corrected, contact your
service representative.
0B81 BMC Firmware Code Area CRC check failed.
0B82 BMC Core Hardware failure.
0B83 BMC 1BF or 0BF check failed.
0B8B BMC progress check timeout.
0B8C BMC command access failed.
0B8D Could not redirect the console - BMC Busy -
0B8E Could not redirect the console - BMC Error -
0B8F Could not redirect the console - BMC
Parameter Error -
0B90 BMC Platform Information Area corrupted.
0B91 BMC update firmware corrupted.
0B8A BMC SEL area full Start the SETUP and select [Server] - [Event Log
configuration] - [Clear All Error Logs] and press Enter
to clear event logs.
0B8F Could not redirect the console BMC
Parameter Error
Turn off the power once and then on again to start the
server. If the error cannot be corrected, contact your
service representative.
0B92 Internal Use Area of BMC FRU corrupted. This is not a fatal error. Turn off the power once and
then on again to restart the server. If the error cannot
be corrected, contact your service representative.
0B93 BMC SDR Repository empty. Turn off the power once and then on again to restart
the server. If the error cannot be corrected, contact
your service representative.
0B94 IPMB signal lines do not respond. This is not a fatal error. Turn off the power once and
then on again to restart the server. If the error cannot
be corrected, contact your service representative.
0B95 BMC FRU device failure.
0B96 BMC SDR Repository failure. Turn off the power once and then on again to start the
server. If the error cannot be corrected, contact your
service representative.
0B97 BMC SEL device failure.
0B98 BMC RAM test error.
0B99 BMC Fatal hardware error.
0B9A BMC not responding. Update the RMC firmware. If the error cannot be
corrected, contact your service representative.
0B9B Private I2C bus not responding. Turn off the power once and then on again to start the
server. If the error cannot be corrected, contact your
service representative.
0B9C BMC internal exception.
0B9D BMC A/D timeout error.
0B9E SDR repository corrupt.
0B9F SEL corrupt.
0BB0 SMBIOS – SROM data read error. Contact your service representative.
0BB1 SMBIOS – SROM data checksum bad.
8100 Memory Error detected in DIMM group #1. Contact your service representative to replace the
DIMM in the relevant group.
8101 Memory Error detected in DIMM group #2.
8102 Memory Error detected in DIMM group #3.
8103 Memory Error detected in DIMM group #4.
8104 Memory Error detected in DIMM group #5.
8105 Memory Error detected in DIMM group #6.
8150 NVRAM cleared by jumper.
Table 31: POST Error Messages (Continued)
Error
code
Error message Recommended Action