EasyManua.ls Logo

NEC Express5800 140Rd-4 - Page 123

NEC Express5800 140Rd-4
340 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-41
NOTES:
When configuration information on the disk array controller and the hard disk do not match
(excluding at replacement of faulty disk array controller), configuration cannot be performed
by selecting the configuration information on the disk array controller. In this case, perform
"Clear Configuration" to create configuration again.
MegaRAID Configuration Utility cannot delete each logical drive. Use Power Console Plus.
3. Make Online.
Puts a hard disk in the FAIL status online.
Select "Objects" "Physical Drive" (select hard disk) "Make Online" from the TOP menu.
4. Battery
Indicate battery information
Select "Objects" "Adapter" "Battery Information" from the top menu.
PRESENT Backup Module
ABSENT
PRESENT Battery Pack
ABSENT
GOOD Temperature
HIGH
GOOD Voltage
LOW
COMPLETED Fast Charging
IN_PROGRESS
No of Cycle ***
Clear battery charge counter
Select "Objects" "Adapter" "Reset Battery Charge Counter" from the top menu. Popup message appears.
Select "Yes" and press Enter.
NOTES:
Clear Battery Charge Counter when you exchange the battery.
The battery backup module must be replaced in two years or 500 times of charge and
discharge.
5. Rebuild Rate
Sets rebuild rate.
Select "Objects" "Adapter" "Rebuild Rate" from the TOP menu.
Can be set in a range from 0% to 100%. The default value (recommended setting value) is "30%."
6. Hard disk information
Checks hard disk information.
Select "Objects" "Physical Drive" (select disk) "View Drive Information" from the TOP menu.

Table of Contents

Related product manuals