3-8
nut is installed
it to be d
with the clips located at the left and right ends, the server may be dropped to cause
efected and also people to be injured severely.
3. After removing the screw located on the rear right of the server, install the adapter bracket on the rear of the server
with the screw removed before.
Screw removed from the
rear of the server.
A
lign the folded part along
with the side of the
chassis.
4. Locate the slide rail assembly on the right side of the rack frame at the position defined by the template.
Stamp (located at the upper
right position of screw hole)
Stamp (located at the lower
right position of screw hole)
NOTES:
Check the direction of installing the slide rail assembly.
Locate the side with the slide bracket at the rear of the rack.
ning. For the rack,
round stamps are provided in 1U. As shown in the figure, locate the slide rail assembly so that
a stamp is positioned at the upper right of the top screw hole of the slide rail assembly.
Make the bracket face facing the outside of the rack.
The front and rear supports of the rack have rectangular holes for screw faste