CHAPTER 2 INSTALLATION
– 87 – NWA-008841-001 Rev.5.0
90ch2001.fm
Drilling
(1) Make a preliminary hole in the concrete, using a drill bit for small-diameter holes.
(2) Drill a hole in the concrete with a drill suitable for a plug bolt a little deeper than the plug bolt
length.
Anchor Bolt Size :10 mm (0.39 inch) DIA for Fixed Equipment
6 mm (0.24 inch) DIA for Stationary Equipment
(3) Insert the anchor bolt into the hole.
(4) Push anchor bolt until the bolt stays permanently in place.
(5) Turn bolt counterclockwise and remove.
(6) Insert bolts correctly into the holes for equipment installation, then tighten them properly.
Drilling Instructions for Anchor Bolt
(3) (4) (5) (6)(1) (2)
INSTALLATION OF MAIN EQUIPMENT

Table of Contents