EasyManua.ls Logo

NEC NEAX 2000 IPS - -48 V DC Power Supply System

NEC NEAX 2000 IPS
619 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER 2 INSTALLATION
– 118 – NWA-008841-001 Rev.5.0
90ch2001.fm
–48 V DC Power Supply System
Cable Connection on PZ-PW135
NOTE 1: Follow the Label on Front Plate of PZ-PW135.
NOTE 2: If GND (Signal GND) has to be separated from FG (Frame GND), remove the link between
GND and FG terminals.
NOTE 3: In Australia, GND and FG are bonded elsewhere, so are not to be linked here. The TRC Earth
connects to the “GND” terminal on every PIM.
NOTE 4: Cable colors in the parentheses are for Australia.
MJ
MN
TO AUXILIARY
EQUIPMENT
ON
SIG
–27 V
FG
GND
IO
TO FRAME GROUND TERMINAL
IN PIM
TO TERMINAL
BLOCK ON BASE
TO PWR0A CONNECTOR ON BWB
TO PWR1 CONNECTOR ON BWB
TO PWR0B CONNECTOR ON BWB
–48 V
DC INPUT
G
TO PWR0C CONNECTOR (–48 V, E) ON BWB
WHITE (BLUE)
BLACK (BROWN)
GREEN (GREEN/YELLOW)
PWR CA-A
PWR CNT CA-D (for PIM1 to PIM7)
PWR CNT CA-E (for PIM0)
AC CORD-B
POWER OUTPUT CABLE (+5 V, –27 V, E)
POWER OUTPUT CABLE (+90 V, CR, E)
SW
–48 V
G
FG
POWER CABLE CONNECTION