CHAPTER 2 INSTALLATION
– 71 – NWA-008841-001 Rev.5.0
90ch2001.fm
Turning Power OFF
(1) Before turning power off, inspect all line/trunk cards’ busy lamps to verify that no cards are
operating.
(2) Turn the SW1 switches of all the PZ-PW121/PZ-PW126 or PZ-PW135 cards to OFF. First, turn OFF
PIM0. Then, turn OFF PIM1 to PIM7.
System Data Backup
CAUTION
If you operate the following without system data backup after system data setting or service
memory setting (registration of the features such as “Call Forwarding” and “Speed Calling
[Speed Dialing]” from a station), the data has been set is invalid.
You must execute the system data backup before the following operations.
-Turning Off the system
-System Initial (reset of MP card)
-Changing the MP card to Off-Line Mode
-Changing the MP card to On-Line Mode after system data setting under Off-Line Mode
You can execute the system data backup by the following two ways.
-Executing the system data backup once a day at the time set by CM43 Y=5>00
(If no data is set, the default setting is 3:00 a.m.)
-Executing the system data backup from MAT/CAT by CMEC Y=6>0:0
Do not reset the MP card, while “SYSD” lamp on the MP card is flashing.