– 279 – NWA-008841-001 Rev.5.0
90ch2002.fm
CHAPTER 2 INSTALLATION
To reset CAT mode:
While “COMMAND = -” is displayed on the LCD:
1. Lift the handset (off hook)
-SPKR/Speaker lamp turns off.
2. Restore the handset (on hook)
-CNF/Conf, FNC/Feature lamps turn off.
-LCD returns to clock.
MAT
Refer to the “MATWorX User Guide”.
Confirming Lamp Indication
After system data entry, confirm proper operation of the system using indicator lamps.
RUN Lamp Flashing (120 IPM)
Check that the RUN lamps of PN-CP24-A/CP24-B/CP24-C/CP24-D card and other application cir-
cuit cards are flashing.
ON Lamps of All PZ-PW121/PZ-PW126 cards Lightning
Check that the ON lamps of all the PZ-PW121/PZ-PW126 cards are lightning and their MJ/MN
lamps have gone out.
BL Lamps Gone Out
Check that the BL lamps of all the line/trunk circuit cards have gone out. If BL lamps are flashing,
it means that the corresponding circuit is in make-busy state or the system data for this card is not
assigned.
For more details of lamp indication, see “CHAPTER 3 LAMP INDICATIONS AND SWITCH SET-
TINGS”. For information of maintenance servicing and troubleshooting of the equipment, refer to the
“Maintenance Manual”.