– 335 – NWA-008841-001 Rev.5.0
90ch3003.fm
The figure in the SWITCH NAME column and the position of in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
NOTE 1: Set the groove on the switch to the desired position.
NOTE 2: When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the
circuit card.
SW1
(Piano Key SW)
1
For normal operation
OFF Not used
2
For normal operation
OFF Not used
3
For normal operation
OFF Not used
4
ON AP No. 4-15
OFF AP No. 20-31
SW2 (Dip SW)
1 - 8 Not used
JP0 (Jumper SW) For normal operation
(Battery backup ON)
DOWN
Not used
(Battery backup OFF)
JP1 (Jumper SW)
UP Not used
For normal operation
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION CHECK
4
3
2
1
OFF
ON
ON
ON
ON
1
2
3
4
5
6
7
8
ON
OFF
UP
DOWN
PN-AP00-B (DBM)