– 375 – NWA-008841-001 Rev.5.0
90ch3003.fm
Switch Settings
The figure in the SWITCH NAME column and the position of in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
NOTE 1: Set the groove on the switch to the desired position.
NOTE 2: When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the
circuit card.
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION CHECK
SENSE
(Rotary SW)
NOTE 1
4-F Set the switch to match the AP Number (04-31) to be
set by CM05.
0-3 Not used
MB (Toggle SW)
NOTE 2
UP For make-busy
For normal operation
SW1
(Piano Key SW)
1 - 3 Not used (Always set to OFF)
4
ON AP No. 04-15
OFF AP No. 20-31
F
4
AP No.
SW1-4: ON
04 05 06 07 08 09 10 11 12 13 14 15
SW1-4: OFF
20 21 22 23 24 25 26 27 28 29 30 31
SW No.
456789ABCDEF
ON
DOWN
4
3
2
1
OFF
ON
OFF
JULY/1/2006
PN-CFTC-A (CFT)