– 392 – NWA-008841-001 Rev.5.0
90ch3003.fm
The figure in the SWITCH NAME column and the position of in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
Continued on next page
SW3 (Dip SW)
1 Always set to ON
2 Always set to ON
3 Always set to ON
4
ON FP No.16
OFF FP No.01-03, 17-19
JPS (Jumper pin) Balanced transmission: 120
(For twisted-pair cable)
LEFT
TA is grounded on the transmission
line: 75 (For coaxial cable)
JPR (Jumper pin) Balanced transmission: 120
(For twisted-pair cable)
LEFT
RA is grounded on the transmission
line: 75 (For coaxial cable)
E1Z (Jumper pin) Line impedance:
120 (For twisted-pair cable)
LEFT
Line impedance:
75 (For coaxial cable)
SRT (Jumper pin)
RIGHT For mounting this card on PIM0
LEFT For mounting this card on PIM1-PIM7
JP (Jumper pin)
Line impedance:
120 (For twisted-pair cable)
DOWN
Line impedance:
75 (For coaxial cable)
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION CHECK
1
2
3
4
ON
ON
ON
ON
RIGHT
RIGHT
RIGHT
UP
PN-DAID-A (DAID)