EasyManua.ls Logo

NEC NEAX 2000 IPS - Page 417

NEC NEAX 2000 IPS
619 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 401 – NWA-008841-001 Rev.5.0
90ch3003.fm
The figure in the SWITCH NAME column and the position of in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
NOTE: When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the
circuit card.
SW3 (Dip SW)
1 Always set to ON
2 Always set to ON
3 Always set to ON
4
ON
When mounting this card on Remote
Site.
OFF When mounting this card on Main Site.
JPS (Jumper pin)
RIGHT
TA is grounded on the transmission
line: 75 (For coaxial cable)
Balanced transmission: 120
(For twisted-pair cable)
JPR (Jumper pin)
RIGHT
RA is grounded on the transmission
line: 75 (For coaxial cable)
Balanced transmission: 120
(For twisted-pair cable)
JP (Jumper pin)
UP
Line impedance:
75 (For coaxial cable)
Line impedance:
120 (For twisted-pair cable)
SWITCH
NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION CHECK
1
2
3
4
ON
ON
ON
ON
LEFT
LEFT
DOWN
PN-DAIF (DAIF)