ā 507 ā NWA-008841-001 Rev.5.0
90ch3004.fm
Switch Settings
The figure in the SWITCH NAME column and the position of in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
NOTE: Set the groove on the switch to the desired position.
B00 Red B channel status
ON : B0 channel of the No. 0 circuit is in use.
OFF : B0 channel of the No. 0 circuit is in idle.
Flash (60 IPM) : ZT is not connected to the No. 0 circuit.
ZT is in make-busy status.
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION CHECK
DL0
(Rotary SW)
NOTE
0-F
For normal operation
1-F Not used
DL1
(Rotary SW)
NOTE
0-F
For normal operation
1-F Not used
LAMP
NAME
COLOR FUNCTION
0
0
0
0
PN-2CSIA (CSI)