– 533 – NWA-008841-001 Rev.5.0
90ch3004.fm
Switch Settings
The figure in the SWITCH NAME column and the position of in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure
and , the setting of the switch varies with the system concerned.
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION CHECK
SW1
(Piano Key SW)
1 Always set to OFF
2 Always set to OFF
3 Always set to OFF
4 Always set to OFF
SW0
(Piano Key SW)
1
No.0
Circuit
(Receiving)
Terminating register is
provided.
OFF
Terminating register is
not provided.
2
No.0
Circuit
(Sending)
Terminating register is
provided.
OFF
Terminating register is
not provided.
3
No.1
Circuit
(Receiving)
Terminating register is
provided.
OFF
Terminating register is
not provided.
4
No.1
Circuit
(Sending)
Terminating register is
provided.
OFF
Terminating register is
not provided.
4
3
2
1
OFF
ON
OFF
OFF
OFF
OFF
4
3
2
1
OFF
ON
ON
ON
ON
ON
PN-2ILCA (ILC)