CHAPTER 1 GENERAL INFORMATION
– 43 – NWA-008841-001 Rev.5.0
90ch1001.fm
Line Conditions of Each Terminal
NOTE 1: The value in the [ ] shows the cable length when local power is supplied.
NOTE 2: When using PN-8DLCL or PN-8DLCP card, it is not available for long line function, even if it
is equipped with Long Line Adapter.
NOTE 3: The DSS/BLF Console requires local AC/DC power supply.
Continued on next page
TERMINAL TYPE CARD TYPE
CABLE LENGTH
(Cable 0.5 φ/24 AWG)
REMARKS
D
term
65 (Series III)
(8 button)
PN-8DLCL/8DLCP
(STANDARD)
300 m (984 ft.) NOTE 2
PN-4DLCM/4DLCQ
(STANDARD)
300 m
[1200 m
(984 ft.)
(3937 ft.)]
PN-2DLCN/4DLCT
(LONG)
850 m
[1200 m
(2788 ft.)
(3937 ft.)]
D
term
65 (Series III)
(24 button)
PN-8DLCL/8DLCP
(STANDARD)
150 m (492 ft.) NOTE 2
PN-4DLCM/4DLCQ
(STANDARD)
150 m
[1200 m
(492 ft.)
(3937 ft.)]
PN-2DLCN/4DLCT
(LONG)
850 m
[1200 m
(2788 ft.)
(3937 ft.)]
DSS/BLF Console
NOTE 3
PN-8DLCL/8DLCP
(STANDARD)
300 m (984 ft.) NOTE 2
PN-4DLCM/4DLCQ
(STANDARD)
1200 m (3937 ft.)
PN-2DLCN/4DLCT
(LONG)
1200 m (3937 ft.)