EasyManua.ls Logo

NEC SL2100 - 2.15 General Purpose;Door Unlock Relay Specifications; 2.16 External Paging Output Specifications; 2.17 BGM;ExMOH Source Input Specifications; 2.18 External Sensor Device Interface Specifications

NEC SL2100
218 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ISSUE 4.0 SL2100
SYSTEM SPECIFICATIONS 213
2.15 General Purpose/Door Unlock Relay Specifications
Table 5-11 General Purpose/Door Unlock Relay Specifications
Item
Specification
Rated Voltage
DC 48 V Maximum
Rated Current
DC 320 mA Maximum
Contact
Normally Open
2.16 External Paging Output Specifications
Table 5-12 External Paging Output Specifications
Item
Specification
Output Impedance
600 Ω @ 1 kHz
Output Level
Nominal 250 mV (-10 dBm)
Maximum Output
400 mV RMS
2.17 BGM/ExMOH Source Input Specifications
Table 5-13 BGM/External MOH Source Input Specifications
Item
Specification
Input Impedance
High Impedance (>10 kΩ)
Input Level
Nominal 250 mV (-10 dBm)
Maximum Input
1 V RMS
2.18 External Sensor Device Interface Specifications
Table 5-14 External Sensor Device Interface Specifications
Applied Voltage during
Sensor Off
Loop Current during
Sensor On
Port Assignment
25 V
40 mA
Program 10-03-05: 1 (Read only)
* Port assignment should be set on Doorphone mode by Hard-
ware-Switch on 082U board.
The External Sensor device configuration shall be assigned by Hardware Switch and applied voltage
during sensor off is supported 25 V type only.
2.19 CPU Board LAN Port Specifications
Table 5-15 CPU Board LAN Port Specifications
Item
Specification
Standard
IEEE802.3 100Base-TX Compliant (Full Duplex only)
Access
CSMA/CD
I/F (Layer 1)
Speed: 100 Mbps Full duplex
Cable: CAT5 or better, Straight/Cross Auto Crossover