FlexPAK 800/1000
EN
22
The inial start-up is to be performed with the acousc enclosure removed to verify the
direcon of rotaon. Ret the acousc enclosure when all checks have been performed.
5.2.1 Check the lter cleaning funcon
When the unit is in Running mode, see Secon ‘6.1.3 Running (Running mode)’, press the
lter cleaning buon, see gure 7, item 8, and check that the lter cleaning procedure
starts. The lter cleaning funcon consists of the Filter Cleaning Valve (FCV), which is a
pneumac cylinder with a valve disc. The FCV is located at the top of the lter housing
under the enclosure, see gure 8, item 6. A disnct change in sound can be heard as the
valve releases atmospheric air into the lter, indicang that the funcon works properly.
See also Secon ‘3.1 Funcon’.
5.2.2 Check the automac start and stop funcon
NOTE! This procedure only works if default PLC sengs are used.
Press the Standby/Running buon to put the unit into Standby mode. The unit is not to
start unl a valve is opened at a workplace acvang its microswitch, or the test start/
lter cleaning buon is pressed, see the top of gure 8 and Secon ‘8.3 Filter cleaning in
Running mode’. When the valve closes, the unit switches over to Idling mode and aer a
delay of approximately 10 seconds, a lter cleaning operaon is performed.
Aer an addional me delay of approximately 12 minutes, the unit will go into Standby
mode.
The lter cleaning delay is set by the DIR_me relay, and the stop delay is set by the SSR_
me relay.
With all valves at the workstaons closed, check that the motor slows down (a disnct
change in sound can be heard), and that switching to Idling mode with lter cleaning takes
place aer approximately 10 seconds.
Approximately 12 minutes aer the unit has switched to Idling mode, it should go to
Standby mode due to the SSR funcon switching o.
5.3 Start the unit
For more informaon regarding inial start-up, see the ‘Installaon and service manual’.
Start the unit as follows:
1. Turn the maintenance switch to posion 1.
2. Check that compressed air is connected to the unit.
3. Press the Standby/Running buon on the control panel, see Figure 7, item 9. The
white lamp lights up and the display shows ‘Standby’.
4. The unit starts when the test start buon is pressed, Figure 7, item 8, or when a valve
is opened at a workstaon.
Always switch o the unit at the end of the shi by pressing the Standby/Running buon
on the control panel, or use the weekly mer, see Secon ‘7.2.3 Weekly mer’.
5.4 Unit operaon modes
FlexPAK 800/1000 has the following four operaon modes:
1. O mode
2. Standby mode
3. Running mode
4. Idling mode