6.1.1 Nederman FlexPAK O (O mode)
The unit is in O mode, which is also the unit’s start menu. The unit can also go into O
mode if something is wrong, such as if an alarm is acvated. The pump motor is o, there is
no vacuum, the FCV is closed, and the unit cannot be acvated by a pilot signal.
TimeToService: The amount of me unl next scheduled service. The
default seng is 2000 hours.
6.1.2 FlexPAK Standby (Standby mode)
The unit is in Standby mode. The pump motor is o, there is no vacuum, the FCV is closed,
and the unit is waing for a pilot signal to go into Running mode.
ESC OK
NEDERMAN
FLEXPAK
Standby
Waing For
Pilot Signal
Mo 15:33
6.1.3 Running (Running mode)
The unit in Running mode. The pump motor is on and the unit generates a vacuum. The
FCV is closed. The current vacuum of the unit is shown on the display, for example, -20 kPa.
ESC OK
Running
kPA -20
DIRTm 00:00 s
OTTmr 00:00 h
Exhaust
Air Temp 60°C
DIRTm: The amount of me before the unit goes into Idling mode. The
default is 10 seconds.
OTTmr: If the Overme mer has been acvated, OTTmr shows the
elapsed me since the overme mer started.
6.1.4 FlexPAK Idling (Idling mode)
The unit in Idling mode. The pump motor is on, there is no vacuum, and the FCV is open.
The unit goes into Idling mode when there has been no pilot signal for the me set in DIR_
Time.
ESC OK
FlexPak
Hi Vacuum Unit
IDLING
Time To StandBy
05:33m
TimeToStandby: The amount of me unl the unit goes into Standby
mode. The default seng is 12 minutes.
6.1.5 Filter Cleaning
The unit is cleaning its main lter.
ESC OK
Filter
Cleanining
Cycles 1
Elapsed 0
Clean 00:00 s
Charge 00:00 s
Cycles: How many cleaning pulses will be carried out.
Elapsed: How many cleaning pulses are made.
Clean: Remaining me for cleaning pulse.
Charge: Remaining vacuum build me; the me unl cleaning pulse is
acvated.
6.2 Warning messages
If a warning is acvated, there is a problem that needs to be corrected, but the unit
connues to work. If a warning message is displayed in the PLC display, the light in the