FlexPAK 800/1000
25
EN
Standby/Running buon ashes one second on, one second o. This 1/1 on/o sequence
connues unl the problem is corrected. See also the PLC Sengs Manual and the
Installaon and Service Manual.
NOTE! There are two excepons to this rule, Secons ‘10.3.1 Time For service’ and
‘6.2.2 Bag Replacement Switch Acvated’.
6.2.1 Dustbin Full
The Bin Level Indicator has detected that the dust bin has been full for 12 minutes. Empty
the dust bin and press
OK
to reset the warning.
ESC OK
Warning!
D u s t b i n F u l l
Th 15:01
Time To Unit
Stop 05:00 m
Reset OK
Clean: Remaining me for cleaning pulse.
Charge: Remaining vacuum build me. The me unl the cleaning pulse
is acvated. Charge = Vacuum building me (Charge me).
Pulse: How many cleaning pulses are made of 3.
6.2.2 Bag Replacement Switch Acvated
The bag replacement switch (SC2) is acvated. It shows the maximum allowed me to
replace the dust bag, and how much me is le to replace the dust bag and turn o the
bag replacement switch before the unit is put into O mode.
If this warning is acvated, the light in the Standby/Running buon is lit for two seconds
and then again in 2 seconds. This 2/2 on/o sequence connues unl the warning is reset.
ESC OK
Bag Replacement
Switch Activated
Time to Unit
Stop 02:00m
Max Time 30:00m
Stop: The remaining me to replace the dust bag before the unit is put
into O mode.
MaxTime: The maximum amount of me allowed to replace the dust
bag.