FlexPAK 800/1000
DA
68
6.3.4 Exhaust Air Temp High
Temperaturen på pumpens aastlu har overskredet den maksimalt lladte grænse på 135 °C.
Når ”Current Value” er faldet l under 90 °C, skal du trykke på den grønne OK-knap
OK
for
at nulslle alarmen. Kontrollér køleluvenlen eller PT100-følerværdierne.
ESC OK
Max Temp Exhaust
Air Exceeded
Unit is Stopped
Limit 135 °C
Current 130 °C
Reset OK